Cell-Crete Home
About Us Projects Services Contact Us Cell-Crete Home
in this section...

Floor

Roof
  • Product Line
  • Roof Projects
  • Low Slope Roof Design
  • Design Consideration
  • Mr. Structural Engineer
  • Comparison
  • Effective Crickets

    Engineered Fill

    Architectural Concrete

    Did You Know...

    By using more heat-reflecting concrete instead of asphalt, Atlanta officials lowered their average city temperature by six degrees!

    Mr. Structural Engineer:

    Take advantage of the most economical (best buy) system when designing your metal deck roof system.

    The Elastizell Insulating Concrete Roof System (**E.I.C.R.S.) will provide added wind and seismic resistance when used in conjunction with B Deck.

    The Elastizell Insulating Concrete Roof System provides increased shear resistance values and allows the use of lighter gauge steel decking to satisfy required loads. Less than 10 pounds per square foot. Added benefits to the owner include fire resistive construction - a permanent base for the roofing membrane, and required insulation values. 2-hour UL fire ratings are available with these systems without below deck fireproofing. For comparison purposes - we have simplified the tables - please refer to ICBO reports 2078, 2757 and 3081 for completed data. **E.I.C.R.S. - consists of a minimum of 2" of Elastizell Insulating Concrete over up to 4" of Expanded Polystyrene Insulation.

    Comparison - Shear Value (q) Verco B Deck (HSB-36) with Rigid Insulation v Elastizell Concrete Roof Insulation System (EICRS)

    GAUGE OF DECKS HSB -36 DECKS SHEARTRANS EICRS
      8' 10' 8' 10' 8' 10'
    22 GAUGE BP 24" O.C. 370   370   920 770
      TSW 24" O.C. 490   680   1230 1140
      TSW 16" O.C.         1360 1290
      TSW 12" O.C. 700   1010   1490 1430
    20 GAUGE BP 24" O.C. 470   560   1040 910
      TSW 24" O.C. 610   810   1300 1210
      TSW 16" O.C.         1460 1390
      TSW 12" O.C. 860   1180   1610 1540
    18 GAUGE> BP 24" O.C. 650 530 740 600 1250 1180
      TSW 24" O.C. 840 830 1040 970 1420 1340
      TSW 16" O.C.         1620 1560
      TSW 12" O.C. 1150 1260 1470 1470 1800 1740
    16 GAUGE BP 24" O.C. 840 680 910 730 1430 1350
      TSW 24" O.C. 1070 1040 1270 1180 1530 1460
      TSW 16" O.C.         1770 1700
      TSW 12" O.C. 1430 1540 1760 1760 1970 1920
    TABLE "V" "VI"
    CELL-CRETE
    "2"
    SOURCE ICBO 2078    
    ICBO 3081
         
    1-2 HR FIRE RATED

    Next...